Seite 1 - 8’ x 16’ Greenhouse

WA RRAN TY65 Fleetwood Drive, Rockaway, NJ 07866Customer Service: (877) 373-3078 Email: [email protected] Hours Helpline: (443) 574-4

Seite 2 - David Schnurman

WWW.RSIWW.COM8 of 50 QTYFan PartsH-71Step 12H-81Step 12 QTYFan PartsH-32Step 12H-12Step 12H-22Step 12H-42Step 12H-61Step 12H-91Steps 12

Seite 3

WWW.RSIWW.COM9 of 50Assemble BaseMake certain the pieces are in the correct positions before securing. Carefully follow the order of assembly to ensur

Seite 4 - Before Starting Assembly:

WWW.RSIWW.COM10 of 50Install T-bolts into inside and outside bolt tracks as shown below. Some of the T-bolts are secured in this step. Most are secure

Seite 5 - Table of Contents

B-8B-8B-8B-8B-5B-5B-5B-5B-5B-5B-5B-5FRONTBACKWWW.RSIWW.COM11 of 50Make certain side profiles are straight and flush. Adjust position of T-bolts in inn

Seite 6 - Constructing a Wood Platform

Prole QTYF-1 756”PanelQTYW-1724” x 57”PanelQTYW-1124” x 57”W-1W-1F-7spacer toolF-1Prole QTYF-7 156”ConnectorsQTYB-3 2S-2C 4S-7 2ConnectorsQTYB-3 8

Seite 7 - List of Parts

Prole QTYF-7 156”ConnectorsQTYB-3 2S-2C 4S-7 2PanelQTYW-1124” x 57”WWW.RSIWW.COM13 of 50NOTE: VIEW FROM OUTSIDE.2.3Remove plastic film and add the l

Seite 8

WWW.RSIWW.COM14 of 50Place one T-bolt on the inside bolt track of the gutter at each end. Hand tighten both T-bolts to hold in place.2.5BNOTE: VIEW F

Seite 9

WWW.RSIWW.COM15 of 50B-3B-5B-3F-7G-1G-2F-1W-1W-1B-5NOTE: VIEWS FROM OUTSIDE UNDER GUTTER.NOTE: VIEWS FROM OUTSIDE UNDER GUTTER.NOTE: The bottom of B-3

Seite 10 - List of Parts (continued)

W-1W-1F-7spacer toolF-83.1DRemove plastic film and fit the W-7 panel into channel in base and F-8 profile. Position F-1 profile so that panel fits in

Seite 11 - Assemble Base

QTYConnectorB-3S-2CS-724256”QTYProleF-7 1Panel QTYW-1 124” x 57”3.1eRemove plastic film and fit another W-1 panel and fit into channel in base and F

Seite 12 - WWW.RSIWW.COM

Thank you for choosing the Monticello Greenhouse ProgramThank You for your PurchaseWe want to thank you for your purchase of the Monticello Greenhouse

Seite 13

F-10F-8W- 7W-1W-1F-1W- 1W- 7F-10F-8W- 1F-7F-1WWW.RSIWW.COM18 of 503.4APlace F-10 profile on W-7 panel. Make sure profile fits snugly between F-8 back

Seite 14 - Assemble Right Wall

WWW.RSIWW.COM19 of 50F-6F-10F-8W-7W-9W-1W-1F-1F-10F-10F-6F-7F-10F-10F-1F-8W-1W-13.5AThe two sets of F-6 and F-10 profiles fit on top of W-1 panels. Li

Seite 15 - Connectors

QTYConnectorB-3S-2CS-7242Prole QTYF-7 156”PanelQTYW-1124” x 57”QTYConnectorB-3S-2CS-77147PanelQTYW-1724” x 57”56”QTYProleF-1 7B-3F-8WWW.RSIWW.COM2

Seite 16

WWW.RSIWW.COM21 of 50G-1G-1G-2G-2G-2NOTE: VIEWS FROM INSIDE.NOTE: VIEW FROM INSIDE.NOTE: At front and back, edge of G-1 gutter profile lines up flush

Seite 17

WWW.RSIWW.COM22 of 50NOTE: VIEWS FROM OUTSIDE UNDER GUTTER.NOTE: VIEWS FROM OUTSIDE UNDER GUTTER.NOTE: The bottom of B-3 connector extends past the ed

Seite 18 - 24” x 57”

WWW.RSIWW.COM23 of 50NOTE: The door frame is 69¼” from the base. To avoid adjusting the placement after assembly, prepare door frame using the exact m

Seite 19

WWW.RSIWW.COM24 of 50NOTE: VIEWS FROM INSIDE.NOTE: VIEWS FROM INSIDE.NOTE: VIEW FROM INSIDE.NOTE: Panels will not fit completely to end of channels. T

Seite 20 - QTYConnectors

WWW.RSIWW.COM25 of 50NOTE: VIEWS FROM INSIDE.NOTE: VIEWS FROM INSIDE.NOTE: VIEW FROM INSIDE.NOTE: Panels will not fit completely to end of channels. T

Seite 21 - QTYProle

B-2S-2CS-2D 81S-7 6ConnectorQTYConnectorQTYS-2A 2S-2B 22D-7 1ProleQTYF-5F-4 1117¼”47 ¼”WWW.RSIWW.COM26 of 50IMPORTANT: F-4 profile is centered to F-5

Seite 22 - Assemble Left Wall

WWW.RSIWW.COM27 of 50IMPORTANT: Bolt track of F-6 front profile is lower than bolt track of G-1 gutter profile.WARNING: The corners of W-3 panels are

Seite 23

WWW.RSIWW.COM1 of 50MONTICELLO Limited Warranty/ Liability Snow Load & Wind Load Warranty & LiabilityThe Monticello Greenhouse described in th

Seite 24

WWW.RSIWW.COM28 of 50NOTE: VIEW FROM OUTSIDE.NOTE: VIEW FROM OUTSIDE.From outside fit F-7 profiles into each side of front. Begin with either side. Ar

Seite 25 - Assemble Front Wall and Gable

WWW.RSIWW.COM29 of 50B-1B-1F-10F-10F-8B-1F-8F-2F-1NOTE: VIEWS FROM OUTSIDE.IMPORTANT: Bolt track of F-6 front profile is lower than bolt track of G-1

Seite 26

WWW.RSIWW.COM30 of 50NOTE: VIEW FROM OUTSIDE.NOTE: VIEW FROM OUTSIDE.NOTE: Panels will not fit completely to end of channels. There will be some space

Seite 27 - Connector

WWW.RSIWW.COM31 of 50S-7S-5A 314B-53B-10 6S-2C12QTYProfile49¾”48½”R-1E2R-12Assemble Roof RidgeMake certain the pieces are in the correct positions bef

Seite 28

WWW.RSIWW.COM32 of 50NOTE: VIEWS FROM OUTSIDE.WARNING: Use two people to install roof ridge. Place ladder in inside of greenhouse. One person will sta

Seite 29 - F-6F-6 G-1

WWW.RSIWW.COM33 of 50Assemble RoofMake certain the pieces are in the correct positions before securing. Carefully follow the order of assembly to ensu

Seite 30 - 28 of 50

WWW.RSIWW.COM34 of 50R-1F-7W-8G-1F-7W-8R-1F-7G-1W-8NOTE: VIEWS FROM OUTSIDE.NOTE: VIEWS FROM OUTSIDE.Working from back right corner, remove plastic f

Seite 31 - Assemble Back Gable

WWW.RSIWW.COM35 of 50B-4S-5B 1S-2C 73ConnectorQTYW-8 2PanelQTY24” x 57”Connector QTYS-7 4W-8W-88.3AHold two profiles together at ridge using one B-4

Seite 32

WWW.RSIWW.COM36 of 50B-4S-5B 1S-2C 104ConnectorQTYW-8 3PanelQTY24” x 57”Connector QTYS-7 10*NOTE: W-10 panels are installed in step 8.7 8.4A8.4DW-8

Seite 33 - Assemble Roof Ridge

WWW.RSIWW.COM37 of 508.5cHold two profiles together in place at ridge using one B-4 connector. Insert two T-bolt assemblies, line up center hole with

Seite 34

WWW.RSIWW.COM2 of 50IntroductionThank you for purchasing the Mojave Edition MonticelloTM Greenhouse. The Monticello line is proudly made in the USA b

Seite 35 - 5’ Bungee Cord

WWW.RSIWW.COM38 of 508.6A Continue working from back to install section five. W-8W-10W-10W-10NOTE: VIEWS FROM OUTSIDE.NOTE: VIEWS FROM OUTSIDE.W-10 3P

Seite 36

WWW.RSIWW.COM39 of 50G-4W-10G-1F-7C-1G-4F-7W-10G-1G-1NOTE: VIEWS FROM OUTSIDE.NOTE: VIEWS FROM OUTSIDE.NOTE: To aid in rain collection and prevent wat

Seite 37

WWW.RSIWW.COM40 of 50Install Roof VentsMake certain the pieces are in the correct positions before securing. Carefully follow the order of assembly to

Seite 38

S-1W-10S-1W-10WWW.RSIWW.COM41 of 50NOTE: VIEW FROM OUTSIDE.NOTE: VIEW FROM OUTSIDE.Screw two S-1 screws through V-4 panel. Line up gripping channel on

Seite 39 - 37 of 50

W-6 2PanelQTY24” x 34”D-9S-9 42ConnectorQTYQTYProle68½”E-2 1E-1 224”E-3 122¼”WWW.RSIWW.COM42 of 50IMPORTANT: You are assembling a right and left doo

Seite 40

WWW.RSIWW.COM43 of 50W-6 2PanelQTY24” x 34”B-3 1S-9 1ConnectorQTYD-9S-9 84D-6S-10 21ConnectorQTYQTYProle68½”E-2 2E-1 224”E-3 122¼”E-2E-1E-2D-9Repeat

Seite 41 - Trim Plate

WWW.RSIWW.COM44 of 50NOTE: VIEW FROM OUTSIDE.NOTE: VIEWS FROM OUTSIDE.IMPORTANT: Make sure door is level. Whennecessary loosen screws holding D-8 hing

Seite 42 - x 24 ¾”

WWW.RSIWW.COM45 of 50NOTE: The S-4 screw is designed to be used with wood. When securing base to foundations made of materials other than wood, use an

Seite 43

Connectors QTYS-2C 2S-72Fan QTYH-8 1Thermostat QTYH-7 1Connectors QTY44S-2DS-5BWWW.RSIWW.COM46 of 50H-7Install Fan and Solar PanelMake certain the pie

Seite 44 - Assemble and Install Doors

Shutter QTYH-6 1Connectors QTYS-2C 8S-7 8Shutter Parts QTYH-2 2H-1 2Tape QTYH-1010’WWW.RSIWW.COM47 of 50Working on the ground, line up holes in H-1 b

Seite 45 - 24” x 34”

WWW.RSIWW.COM3 of 50Safety AdviceGeneral Order of AssemblyTools NeededTable of Contents• The greenhouse must be positioned and fixed on a flat level

Seite 46

WWW.RSIWW.COM48 of 50H-4H-3H-3H-4H-912.5DInstall H-9 solar panel on H-3 profiles and secure with S-2D nut.H-9S-5DS-11S-2DS-5DS-11S-2DS-5DS-11S-2DS-5DS

Seite 47 - Secure to Platform

WWW.RSIWW.COM49 of 50Working from inside. Drill hole through polycarbonate.12.6ANOTE: VIEW FROM INSIDE.H-912.6BConnect wires to Solar Panel. Push the

Seite 48 - Thermostat QTY

WWW.RSIWW.COM50 of 50H-7H-8Charge ControllerBattery12.6eOPTIONAL CHARGE CONTROLLER AND BATTERY: For accurate wiring using charge controller and batter

Seite 49 - Tape QTY

WWW.RSIWW.COM4 of 50Constructing a Wood PlatformIMPORTANT: It is very important to begin with a level surface. Check your foundation to ensure it is l

Seite 50 - Solar Panel Parts QTY

WWW.RSIWW.COM5 of 50List of PartsWARNING: Profiles with cut edges and/or drilled holes are sharp. Use extreme caution when handling.The greenhouse is

Seite 51 - Wire QTY

WWW.RSIWW.COM6 of 50List of Parts (continued)WARNING: Use extreme caution when handling panels with cut edges. The corners are sharp.24”68½”22¼”68½”E-

Seite 52 - Controller

WWW.RSIWW.COM7 of 50List of Parts (continued)D-420’Step 10D-71Step 10D-84Step 5D-98Step 10D-102Step 10G-4G-4EC-1C-2V-344423Step 8Step 8Steps5,6Step 7S